VMware HCI Master Specialist 5V0-21.21 exam is for the VMware Certified Master Specialist – HCI 2022 certification, which validates a candidate’s ability to deploy and manage a software-defined storage solution with VMware vSAN. To pass the VMware 5V0-21.21 exam successfully, candidates are highly recommended to choose the VMware 5V0-21.21 real exam dumps, which give you the latest 5V0-21.21 practice exam questions and answers to ensure that you can pass the actual VMware HCI Master Specialist exam on the first attempt.

VMware HCI Master Specialist 5V0-21.21 Free Exam Dumps Are Available Too

Page 1 of 2

1. A company hosts a vSAN 7 stretched cluster for all development workloads. The original sizing of a maximum of 250 concurrent workloads in the vSAN cluster is no longer sufficient and needs to increase to at least 500 concurrent workloads within the next six months.

To meet this demand, the original 8-node (4-4-1) cluster has recently been expanded to 16 nodes (8-8-1).

Which three additional steps should the administrator take to support the current growth plans while minimizing the amount of resources required at the witness site? (Choose three.)

2. During a maintenance action on a vSAN node, a vSAN administrator noticed that the default repair delay time is about to be reached.

Which two commands must be run to extend the time? (Choose two.)

3. A customer has upgraded to vSAN 7, but there is still an existing legacy host which must be removed from the vSAN cluster.

Which three steps must an administrator take to successfully remove this host from the vSAN cluster? (Choose three.)

4. An administrator is planning to deploy workloads on a six node vSAN cluster, and all nodes are distributed equally across three racks.

Which action is required to ensure that the workload VMs remain compliant with the default vSAN policy after a complete rack failure?

5. Due to the success of the recently deployed developer-only private cloud solution, a company has a new requirement to at least double the usable capacity in their all-flash vSAN cluster.

The vSAN cluster is deployed into a co-located datacenter that is owned by a third-party hosting company. The hosting company charges a fixed monthly cost for rack space and power consumption. The service owner has been given a limited budget for additional hardware purchases, but not for on-going co-location costs.

The current vSAN cluster has the following configuration:

* 10 vSAN Nodes with 2 CPUs (20 cores), 512 GB RAM

* 1 Disk Group per vSAN node

- 1 x 400 GB

- 4 x 1.8 TB

* De-duplication and Compression is enabled.

* vSAN Capacity is currently:

- Total: 72 TB

- Usable: ~40 TB (FTT1/RAID1) and ~60 TB (FTT1/RAID5).

As a result of any action taken, the service owner would like to ensure that overall availability of the vSAN cluster is increased.

Which two recommendations meet the requirement to increase capacity while maintaining service availability? (Choose two.)

6. Which statement accurately describes the result when proper VM Storage Policy Affinity Rules on a stretched vSAN cluster are set?

7. An administrator is setting up vSAN file services on a vSAN cluster.

Which two security policies on the distributed port groups are automatically enabled in the process? (Choose two.)

8. An administrator is tasked with preparing for a Cross vCenter migration in a stretched vSAN cluster where the virtual machines migration will be orchestrated via VMware Site Recovery Manager.

Which action should the administrator take so the migration is successful?

9. Upon investigating a workload performance issue, a vSAN administrator observed a high backend IOPs on a vSAN cluster.

Which two causes explain this behavior? (Choose two.)

10. 1.An administrator is planning to deploy cloud-native workloads onto the vSAN Direct datastore.

Which storage policy structure rule is supported?


 